This paper presents the results of a severe accident parametric sensitivity study performed on a model of a generic integral pressurized water reactor (iPWR). The analyzed sequence is a loss of coolant accident (LOCA)-type scenario. postulating that safety systems are not available. In this work. https://www.chiggate.com/